Invitrogen™ CyQUANT™ Cell Proliferation Assays
CyQUANT cell proliferation assays are fast and highly sensitive fluorescence methods for counting cells to assess cell growth and cytotoxicity in microplate format. These assays use fluorescent nucleic-acid-binding dyes to measure cell number based on DNA content.
| For Use With (Application) | Proliferation Assay |
|---|
Molecular Probes™ LIVE/DEAD™ Fixable Violet Dead Cell Stain Kit, for 405 nm excitation
The LIVE/DEAD™ Fixable Violet Dead Cell Stain Kit is used to determine the viability of cells prior to the fixation and permeabilization required for intracellular antibody staining, or prior to elimination of biohazardous materials using formaldehyde fixation.
| Shipping Condition | Room Temperature |
|---|---|
| dimExcitationWavelengthRange | 416 nm |
| Description | LIVE/DEAD™ Fixable Violet Dead Cell Stain Kit, for 405 nm excitation |
| Form | Solid |
| Solubility | DMSO (Dimethylsulfoxide) |
| Color | Violet |
| Emission | 451 |
| Dye Type | LIVE/DEAD™ Fixable Violet Dead Cell Stain |
| For Use With (Application) | Viability Assay |
| Detection Method | Fluorescence |
| Cell Type | Eukaryotic Cells |
| Cell Permeability | Impermeant |
| Format | Tube(s) |
| Product Type | Stain |
| For Use With (Equipment) | Flow Cytometer |
| Product Line | LIVE/DEAD |
Molecular Probes™ Fluo-4, AM, cell permeant
Fluo-4 is an analog of fluo-3 with the two chlorine substituents replaced by fluorines, which results in increased fluorescence excitation at 488 nm and consequently higher fluorescence signal levels.
Invitrogen™ CellTrace™ Far Red Cell Proliferation Kit, for flow cytometry
CellTrace™ Far Red Cell Proliferation Kit, for flow cytometry
| Shipping Condition | Room Temperature |
|---|---|
| Format | Tube(s) |
| Product Type | Cell Proliferation Kit |
| For Use With (Equipment) | Flow Cytometer |
| Product Line | CellTrace |
| Detection Method | Fluorescence |
Invitrogen™ Calcein AM, Cell-permeant Green and Blue Dyes
Calcein AM is a cell-permeant dye that can be used to determine cell viability in most eukaryotic cells. In live cells, the non-fluorescent Calcein AM is converted to green or blue fluorescent Calcein, after acetoxymethyl ester hydrolysis by intracellular esterases.
| Shipping Condition | Room Temperature |
|---|---|
| Content And Storage | Store in freezer (-5°C to -30°C) and protect from light. |
| For Use With (Equipment) | Fluorescence Microscope |
| Reagent Type | Cell Tracker Compounds, Cell Labeling Reagents |
| Dye Type | Other Label(s) or Dye(s) |
| For Use With (Application) | Cell Tracing,Cell Tracker |
Invitrogen™ Image-iT™ TMRM Reagent (mitochondrial membrane potential indicator)
Healthy mitochondrial membranes maintain a difference in electrical potential between the interior and exterior of the organelle, referred to as a membrane potential.
Invitrogen™ LIVE/DEAD™ Fixable Far Red Dead Cell Stain Kit, for 633 or 635 nm excitation
The LIVE/DEAD™ Fixable Far-Red Dead Cell Stain Kit is used to determine the viability of cells prior to the fixation and permeabilization required for intracellular antibody staining, or prior to elimination of biohazardous materials using formaldehyde fixation.
| Shipping Condition | Room Temperature |
|---|---|
| dimExcitationWavelengthRange | 633 nm |
| Description | LIVE/DEAD™ Fixable Far Red Dead Cell Stain Kit, for 633 or 635 nm excitation |
| Form | Solid |
| Solubility | DMSO (Dimethylsulfoxide) |
| Color | Far-red |
| Emission | 655 |
| Dye Type | LIVE/DEAD™ Fixable Far Red Dead Cell Stain |
| For Use With (Application) | Viability Assay |
| Detection Method | Fluorescence |
| Cell Type | Eukaryotic Cells |
| Cell Permeability | Impermeant |
| Format | Tube(s) |
| Product Type | Stain |
| For Use With (Equipment) | Flow Cytometer |
| Product Line | LIVE/DEAD |
Invitrogen™ LIVE/DEAD™ Fixable Near-IR Dead Cell Stain Kit, for 633 or 635 nm excitation
Determines the viability of cells prior to the fixation and permeabilization required for intracellular antibody staining or prior to elimination of biohazardous materials using formaldehyde fixation.
| Shipping Condition | Room Temperature |
|---|---|
| dimExcitationWavelengthRange | 633 nm |
| Description | LIVE/DEAD™ Fixable Near-IR Dead Cell Stain Kit, for 633 or 635 nm excitation |
| Form | Solid |
| Solubility | DMSO (Dimethylsulfoxide) |
| Color | Near-IR |
| Dye Type | LIVE/DEAD™ FixableNear-IR Dead Cell Stain |
| For Use With (Application) | Viability Assay |
| Detection Method | Fluorescence |
| Cell Type | Eukaryotic Cells |
| Cell Permeability | Impermeant |
| Format | Tube(s) |
| Product Type | Stain |
| For Use With (Equipment) | Flow Cytometer |
| Product Line | LIVE/DEAD |
Molecular Probes™ LIVE/DEAD™ Fixable Aqua Dead Cell Stain Kit, for 405 nm excitation
The LIVE/DEAD™ Fixable Aqua Dead Cell Stain Kit is used to determine the viability of cells prior to the fixation and permeabilization required for intracellular antibody staining, or prior to elimination of biohazardous materials using formaldehyde fixation.
| Shipping Condition | Room Temperature |
|---|---|
| dimExcitationWavelengthRange | 375 nm |
| Description | LIVE/DEAD™ Fixable Aqua Dead Cell Stain Kit, for 405 nm excitation |
| Form | Solid |
| Color | Aqua |
| Emission | 526 |
| Dye Type | LIVE/DEAD™ Fixable Aqua Dead Cell Stain |
| For Use With (Application) | Viability Assay |
| Detection Method | Fluorescence |
| Cell Type | Eukaryotic Cells |
| Cell Permeability | Impermeant |
| Product Type | Stain |
| For Use With (Equipment) | Flow Cytometer |
| Product Line | LIVE/DEAD |
Molecular Probes™ Click-iT™ Plus EdU Alexa Fluor™ 647 Flow Cytometry Assay Kit, 50 rxn(s)
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Click-iT™ Plus EdU Alexa Fluor™ 647 Flow Cytometry Assay Kit
Molecular Probes™ SYTOX™ Blue Dead Cell Stain, for flow cytometry
SYTOX™ Blue dead cell stain is a simple and quantitative single-step dead-cell indicator for use with violet laser equipped flow cytometers.
Molecular Probes™ Click-iT™ EdU Alexa Fluor™ 647 Flow Cytometry Assay Kit
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Click-iT™ EdU Alexa Fluor™ 647 Flow Cytometry Assay Kit
| Shipping Condition | Room Temperature |
|---|---|
| Content And Storage | Contains EdU (5-ethynyl-2' -deoxyuridine), Alexa Fluor™ 647 azide, anhydrous dimethylsulfoxide (DMSO), Click-iT™ fixative, Click-iT™ saponin-based permeabilization and wash buffer, copper (II) sulfate,, and Click-iT™ EdU buffer additive. |
| Format | Tube(s) |
| Product Type | Flow Cytometry Assay Kit |
| For Use With (Equipment) | Flow Cytometer |
| Emission | 650/670 |
| Green Features | Less hazardous |
| Dye Type | Alexa Fluor™ 647 |
| Detection Method | Fluorescence |
Molecular Probes™ Click-iT™ EdU Alexa Fluor™ 488 Flow Cytometry Assay Kit
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Click-iT™ EdU Alexa Fluor™ 488 Flow Cytometry Assay Kit
| Shipping Condition | Room Temperature |
|---|---|
| Content And Storage | Contains EdU (5-ethynyl-2' -deoxyuridine), Alexa Fluor™ 488 azide, anhydrous dimethylsulfoxide (DMSO), Click-iT™ fixative, Click-iT™ saponin-based permeabilization and wash buffer, copper (II) sulfate,, and Click-iT™ EdU buffer additive. |
| Format | Tube(s) |
| Product Type | Flow Cytometry Assay Kit |
| For Use With (Equipment) | Flow Cytometer |
| Emission | 488 |
| Green Features | Less hazardous |
| Dye Type | Alexa Fluor™ 488 |
| Detection Method | Fluorescence |
Invitrogen™ CellTrace™ CFSE Cell Proliferation Kit, for flow cytometry
CellTrace™ CFSE Cell Proliferation Kit is used for in vitro and in vivo labeling of cells to trace multiple generations using dye dilution by flow cytometry.
| Shipping Condition | Room Temperature |
|---|---|
| Format | Tube(s) |
| Product Type | Cell Proliferation Kit |
| For Use With (Equipment) | Flow Cytometer |
| Emission | 488 |
| Product Line | CellTrace |
| Detection Method | Fluorescence |
Molecular Probes™ Click-iT™ EdU Pacific Blue™ Flow Cytometry Assay Kit
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Click-iT™ EdU Pacific Blue™ Flow Cytometry Assay Kit