Syringes and Needles

SGE™ Manual Syringes For Rheodyne™ and Valco™ Valves

The injection size sets the injection volume 1MR-LC-GT 1ML SYRINGE

GE Healthcare Whatman™ 30mm SPARTAN™ HPLC Certified Syringe Filters with Slip Luer Outlet

Provides reproducible results from the filtration of organic and aqueous solutions in HPLC. Whatman™ 30mm Spartan™ HPLC Certified Syringe Filters with Slip Luer is resistant to common HPLC solvents and exhibits very low levels of extractables that could otherwise interfere with analysis. X50 FP 30/0.45 RC-SREADY-TO-USE

Trajan™ Diamond Thermo RSH 100μL GC Autosampler Syringes

Improves the sensitivity of your MS analysis with reduced non specific sample interaction and increased analyte recovery. Needle cone tip style, gauge 23 ultra smooth

Hamilton™ Microliter 700 Cemented Autosampler Syringes, Model 75 N

The 700 series syringe is the original hand-fitted Hamilton syringe. This series of syringes is ideal for dispensing volumes from 0.5 µL up to 500 µL. A variety of different terminations and needle options are available in this series. 75 N 5µL Syr (26s/51/2)length 51mm

Microspec™ Plastic Culture Needles

Transfer and inoculate living microorganisms X1000 Plastic Culture Needles, Sterile Gamma

SGE™ Gastight Syringes: Removable-Needle Models

Suitable for liquid and gas samples SYRINGE,1ML,REMOVEABLE NEEDLE,GAS/LIQIUID TIGHT

Gosselin™ Pipette Container

An excellent option for disposal of waste in the laboratory. Gosselin™ Pipette Container features a sturdy polypropylene plastic body. X16 Pipettes container 5L yellow

Sartorius™ Minisart™ RC Syringe Filters

Combines rapid small volume particle removal filtration with maximum user convenience. Sartorius™ Minisart™ RC Syringe Filters utilize a regenerated cellulose membrane for clarification of small volume samples. Choose from 0.2 and 0.45μm pore sizes in 15, 25 and 4mm diameter filters. X50 FILTERS,MINISART RC25 0.2µM (PACK OF 50)

Hamilton™ 800 Series Microliter™ Replacement Syringe Barrels

Barrels available with or without needle. Choose removable needle (RN) or cemented needle (N) termination.  (See exact specifications below.)

802 RN 25µL B/P w/o ndl.

Trajan™ Replacement Needles for 25 to 500μL Removable Needle Syringes

Replacement Needles for 25 to 500uL Syringes for use in Chromatography X5 NEEDLE,25-500µL,50MM,FLAT TIP 24 GAUGE (PACKOF 5)

SGE™ Syringes with Valves

Prefitted with removable needle and valve or Luer Lock valve 2.5MDR-V-GT 2.5ML SYRINGE

Hamilton™ Tubing Retention Clips

Holds tubing in place with beakers and other vessels. Tub Clip

Hamilton™ Constant Rate-700 HPLC Syringes & Replacement Parts

Syringes are designed to delive reasy, reproducible injection of liquid samples into an injector on HPLC instrumentation. The CR-700 standardizes three major variables: sample volume, rate of injection, and depth of needle penetration. Even when operated by different technicians, the CR-700 provides reproducibility of +1% of the total syringe volume in routine procedures. CR700-200 10-200µL(22/51/3)

Thermo Scientific™ Target2™ Nylon Syringe Filters

Ensure cleaner sample extracts by removing interfering materials and fine particles prior to injection with these robust nylon syringe filters. Ideal for general HPLC use. X100 30MM NYLON SYRINGE FILTER 5.0UM

SGE™ Gastight Syringes: Fixed Needle Models

Suitable for liquid and gas samples SYRINGE,50µL FIXED NEEDLE 50MM,GAS TIGHT

Thermo Scientific™ Target2™ PTFE Syringe Filters

Ensure cleaner sample extracts by removing interfering materials and fine particles prior to injection with these robust PTFE syringe filters. X100 4 MM TEFLON SYRINGE FILTER .2 UM

Hamilton™ Microliter™ and Gastight™ Agilent 7673, 7683, 7693 and 6850 ALS GC Syringes: Model 1701N

Designed to work with Agilent 7673, 7683, 7693 and 6850 Automatic Liquid Sampler (ALS) gas chromatography (GC) autosamplers 1701 ASRN 10µL (26s/43/AS)AUTOSAMP LER GAS TIGHT 0.47MM O.D.

Trajan™ Diamond MS Manual Syringes

Improves the sensitivity of your MS analysis with reduced non specific sample interaction and increased analyte recovery. Manual syringe designed to improve sensitivity

Fisherbrand™ Biohazard Sharp Object Safety Pouch Stand

Offers protection against cuts by contaminated sharp objects during work in labs, clinics and medical offices Sharp Safety Pouch Stand

Socorex™ Stainless Steel Straight Drenchers

Use Socorex™ Stainless Steel Straight Drenchers for animal feeding and dosing. These precision-assembled stainless-steel feeding needles are ideal for the delivery of fluid and are reusable since they are autoclavable. X3 Drencher, straight, 1.2x51mm, animal mouth andnose canulas

Hamilton™ PTFE Tubing Adapted to Femaile Luer Lock

Connect to a syringe or other component TUB PTFE 1XHUB 2X1X300

Merck™ HPF Millex™ Nonsterile 25mm Syringe Filters

Achieve up to 50% greater throughput and easier filtration than traditional syringe filters. MilliporeSigma™ HPF Millex™ Nonsterile 25mm Syringe Filters feature a choice of nylon or PVDF membranes for optimal, fine filtration. Non-sterile filters are compatible with multiple Zymark workstations. X1000 Millex-HPF HN 25mm Nylon .45um Non-sterile

GE Healthcare Whatman™ Glass Mini-UniPrep G2 Syringeless Filters: 0.2μm with Normal Caps

Prepare UHPLC/HPLC samples 3X faster with the purity of glass. Whatman™ Mini-UniPrep™ G2 Syringeless Filters combine a membrane filter, glass autosampler vial, septum and plunger into a single device for easier handling and fewer consumables. X100 MUP G2 0.2uM RC

Hamilton™ 700 and 1700 Series Gastight™ and Microliter™ Digital Syringes: N Termination

Easily achieves precision up to 0.5% while dispensing volumes from 500μL down to 50nL Digital syringe 725N 250µL DS (22/51/3)

Hamilton™ 1700/1000 Series Gastight™ Instrument Syringes: DX Termination

Syringes are designed to fit into, or with, various different instruments such as the MICROLAB™ 500 and MICROLAB 1000 1705 DX 50µL Syr

GE Healthcare Whatman™ Puradisc 13mm GMF Syringe Filters

Constructed of Glass Microfiber. Whatman™ Whatman™ Puradisc 13mm GMF Syringe Filters are hydrophilic with excellent compatibility with organic solvents and strong acids and bases. X100 PURADISC 13 GF/C 13MM

Trajan™ Replacement Needles for Luer-Lock Syringes

Bevel tip style. Trajan Scientific and Medical™ Replacement Needles for Luer-Lock Syringes are supplied in packs of 5. X5 NLL-7/23 LUER NEEDLE

Hamilton™ Small Hub Removable Needles (2.5 - 100μL Syringes)

Can be used with removable (RN)-style syringes that are 100μL and smaller. X6 RN NEEDLE (26s/51/3)S

Hamilton™ Kel-F Hub Blunt Point Needles (Luer Lock)

Kel-F hub (KF) needles can be used with Luer Tip (LT) and PTFE Luer Lock (TLL) syringes and connectors. Standard needle length is 2 in. (51mm). Custom lengths and point styles are available. X6 Needles Hamilton Kel-F Hubpoint style 3 Kel-F

Hamilton™ 700/1700 Series Microliter/Gastight™ Syringes

Hamilton Company offers the most comprehensive selection of standard and custom syringes in the industry. Each is manufactured to achieve the highest level of accuracy and precision possible. 1705 RN 50uL SYR W/O NDL.borosilicate glass syringe/steel plunger/PTFE

  spinner