Filtered Search Results
Applied Biosystems™ TaqMan™ Universal PCR Master Mix
TaqMan Universal PCR Master Mix is the ideal reagent solution when you need a master mix for multiple 5' nuclease DNA applications.
| Polymerase | AmpliTaq Gold DNA Polymerase |
|---|---|
| GC-Rich PCR Performance | High |
| Product Type | Universal PCR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7000 System, 7300 System, 7500 System, 7700 System, 7900HT System,Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, GeneAmp 9600, StepOne™, Standard Mode, StepOnePlus™, Standard Mode |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Standard |
| For Use With (Application) | Gene Expression,Genotyping,miRNA analysis |
| PCR Method | qPCR |
| Product Line | TaqMan |
| Detection Method | Primer-probe |
Applied Biosystems™ SeqStudio™ Cartridge v2
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
SeqStudio™ Cartridge v2 is an all-in-one, easy-to-use reagent cartridge that includes capillaries, universal polymer, buffer, and pump required to run on the SeqStudio Genetic Analyzer System. The universal polymer allows for flexibility to perform Sanger sequencing and fragment analysis on the same instrument, with the same cartridge.
Applied Biosystems™ resDNASEQ™ Quantitative E. coli DNA Kits
This quantitative PCR (qPCR)-based kit, part of the resDNASEQ™ E. coli Residual DNA Quantitation System, enables highly sensitive quantitation of host cell DNA from E. coli expression systems, typically in less than 4 hours.
| No. of Reactions | 100 Reactions |
|---|---|
| Format | Kit |
| Label or Dye | FAM |
| Quantity | 100 reactions |
| Host Cell | E.coli |
| PCR Method | qPCR |
| Product Line | resDNASEQ |
| Detection Method | Primer-probe |
Applied Biosystems™ GeneScan™ 500 ROX™ dye Size Standard
The GeneScan™ 500 ROX™ Size Standard is an internal lane size standard developed for use with the Applied Biosystems fluorescence-based DNA electrophoresis systems.
| For Use With (Equipment) | 3730xl DNA Analyzer, 3730 DNA Analyzer, 3500 Series Genetic Analyzers, SeqStudio Flex Series Genetic Analyzers, SeqStudio Genetic Analyzer |
|---|---|
| Label or Dye | ROX |
| Product Line | GeneScan, ROX |
Applied Biosystems™ MicroAmp™ 48-Well Optical Adhesive Film
Reduces the chance of well-to-well contamination and sample evaporation when applied to a 48-well microplate
| Plate Compatibility | 48-well Plate |
|---|---|
| Shipping Condition | Room Temperature |
| No. of Wells | 48 |
| Product Type | Film, Seal, or Applicator |
| For Use With (Equipment) | StepOne™, |
| Color | Optical |
| Material | Polyester |
| Adhesive | Pressure Sensitive |
| Product Line | MicroAmp |
Applied Biosystems™ PowerUp™ SYBR™ Green Master Mix for qPCR
Pre-formulated, optimized, universal 2X master mix for real-time PCR workflows.
| Shipping Condition | Wet Ice |
|---|---|
| InhibitorToleranceSimple | Medium |
| Concentration | 2X |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Multiplex Capability | Single-plex |
| Detection Method | SYBR |
| Includes | dUTP, UNG/UDG |
| Thermostability | 72 hr., Assembled Reaction |
| Polymerase | Dual-Lock Taq DNA Polymerase |
| Format | Tube |
| Product Type | Real Time PCR SYBR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio 12k Flex, QuantStudio 3, QuantStudio 5, QuantStudio 6 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio 7 Flex, StepOne, StepOnePlus, ViiA 7 System |
| Sample Type | DNA |
| Reaction Speed | Fast or Standard |
| Target Specificity | cDNA or gDNA only |
| Product Line | PowerUP, SYBR |
Applied Biosystems™ AgPath-ID™ One-Step RT-PCR Reagents
AgPath-ID™ One-Step RT-PCR Reagents are designed for sensitive, robust amplification of RNA targets using a rapid single-tube TaqMan™ real-time reverse transcription PCR (RT-PCR) strategy.
| Shipping Condition | Dry Ice |
|---|---|
| GC-Rich PCR Performance | High |
| Fidelity (vs. Taq) | 25 X |
| Description | Works on all AB platforms, but is optimized for the 7500. |
| Reverse Transcriptase | ArrayScript™ |
| Concentration | 25X |
| PCR Method | 1-step RT-qPCR |
| Detection Method | Primer-probe |
| Polymerase | AmpliTaq Gold DNA Polymerase |
| Format | Tube |
| Product Type | One-Step RT-PCR Reagent |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 System, 7500 Fast System, 7900HT System, StepOne™, StepOnePlus™, ViiA™ 7 System, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio™ 12k Flex, QuantStudio™ Absolute Q Digital PCR System |
| Sample Type | RNA |
| Reaction Speed | Standard |
| Product Line | AgPath-ID, Ambion |
Applied Biosystems™ PowerTrack™ SYBR Green Master Mix for qPCR
PowerTrack SYBR Green Master Mix is a pre-formulated, optimized, universal 2X master mix for real-time PCR workflows with built-in visual dye–based indicators for accurate reaction set up.
| Shipping Condition | Dry Ice |
|---|---|
| Content And Storage | • PowerTrack SYBR Green Master Mix • 40X Yellow Sample Buffer Store at -20±5°C in the dark. |
| InhibitorToleranceSimple | High |
| Concentration | 2X |
| For Use With (Application) | Gene Expression,Microbial Detection |
| PCR Method | qPCR |
| Multiplex Capability | Single-plex |
| Detection Method | SYBR |
| Includes | dUTP, UNG/UDG |
| Thermostability | 8 hr., Assembled Reaction |
| Polymerase | Taq DNA Polymerase |
| Format | Tube |
| Product Type | Real Time PCR SYBR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT Fast System, 7900HT System, QuantStudio 3, QuantStudio 5, QuantStudio 6 Flex, QuantStudio 6 Pro, QuantStudio 7 Flex, QuantStudio 7 Pro, QuantStudio 12K Flex, Bio-Rad CFX Connect, Bio-Rad CFX384 Touch, Bio-Rad CFX96 Touch, BioRad CFX96, BioRad iCycler iQ, BioRad iQ5, BioRad MyiQ, ViiA 7 System, StepOne System, MJ Chromo4, MJ Opticon, StepOnePlus System, Roche LightCycler 480, Stratagene Mx3000P, Stratagene Mx3005P, Stratagene Mx4000 |
| Sample Type | DNA |
| Reaction Speed | Fast or Standard |
| Target Specificity | cDNA or gDNA only |
| Product Line | Applied Biosystems |
Applied Biosystems™ MagMAX™ DNA Multi-Sample Ultra 2.0 Wash I Solution
This Wash I solution is included in the MagMAX DNA Multi-Sample Ultra 2.0 Kit.
Applied Biosystems™ GeneAmp™ dNTP Blend (100 mM)
GeneAmp dNTPs are deoxynucleotide triphosphates dissolved in glass-distilled water and titrated to pH 7.0 with NaOH. Each vial contains a blend of 100 mM solution of dNTP (25 mM each of dATP, dCTP, dGTP and dTTP).
| Shipping Condition | Dry Ice |
|---|---|
| Form | Liquid |
| Concentration | 100 mM |
| For Use With (Application) | Standard PCR |
| Product Line | GeneAmp |
Applied Biosystems™ DS-33 Matrix Standard Kit (Dye Set G5)
Software for these instruments uses the multicomponent matrix to automatically analyze the five different colored fluorescent dye-labeled samples.
Applied Biosystems™ TaqMan™ Universal Master Mix II, no UNG
TaqMan Universal Master Mix II is a convenient mix of components (except primers, probes, template, and water) necessary to perform a real-time polymerase chain reaction (PCR).
| GC-Rich PCR Performance | High |
|---|---|
| Content And Storage | Store at 2°C to 8°C in the dark. Guaranteed minimum shelf life is 60 days (exact expiry date printed on product and CofA). |
| Fidelity (vs. Taq) | 2 X |
| Purity or Quality Grade | UP (Ultra Pure) |
| Concentration | 2X |
| For Use With (Application) | Gene Expression,Genotyping,miRNA analysis |
| PCR Method | qPCR |
| Detection Method | Primer-probe |
| Polymerase | AmpliTaq Gold DNA Polymerase |
| Product Type | Universal Master Mix II |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7300 System, 7500 System, 7900HT System,Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, StepOne™, Standard Mode, StepOnePlus™, Standard Mode, ViiA™ 7 System |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Standard |
| Product Line | TaqMan |
Applied Biosystems™ TaqMan™ Fast Virus 1-Step Multiplex Master Mix for qPCR (No ROX)
TaqMan Fast Virus 1-Step Multiplex Master Mix (No ROX) is designed to enable dye flexibility for multiplexing up to four different RNA/DNA targets for high-throughput RT-qPCR.
| Shipping Condition | Dry Ice |
|---|---|
| InhibitorToleranceSimple | High |
| Concentration | 4X |
| For Use With (Application) | Microbial Detection,Gene Expression,DNA Quantitation,Presence/Absence |
| PCR Method | 1-step RT-qPCR |
| Multiplex Capability | Up to 4-plex |
| Detection Method | Primer-probe |
| Thermostability | Not Applicable |
| Passive Reference Dye | None |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 6 Pro, QuantStudio™ 7 Flex, QuantStudio™ 7 Pro, StepOne™, StepOnePlus™, ViiA™ 7 System |
| Sample Type | RNA, DNA |
| Reaction Speed | Fast or Standard |
| Target Specificity | RNA only, Both RNA and DNA |
| Hot Start | Built-In Hot Start |
Applied Biosystems™ Sequencing Standard, BigDye™ Terminator v1.1, for 3500/SeqStudio™ Flex
The DNA contained in the preparation has been lyophilized to maximize stability.The two hydrolytic enzymes used in this kit, shrimp alkaline phosphatase and exonuclease I, effectively remove excess dNTPs and primers.