Thermo Scientific™ POROS™ CaptureSelect™ FSH Affinity HPLC Columns

Code produit 18416428 Tous les produits Thermo Scientific Produits
Modifier l'affichage
Click to view available options
Longueur (métrique):
30 mm
50 mm
100 mm
Diamètre (métrique):
2.1 mm
4.6 mm
Conditionnement:
1 pièce
3 product options available for selection
Product selection table with 3 available options. Use arrow keys to navigate and Enter or Space to select.
Code produit Longueur (métrique) Diamètre (métrique) Conditionnement
18416428 30 mm 2.1 mm 1 pièce
18496558 50 mm 4.6 mm 1 pièce
18466648 100 mm 4.6 mm 1 pièce
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 3 options available.
3 options
Les retours ne sont pas autorisés pour ce produit. Afficher la politique du retour.
Code produit 18416428 Fournisseur Thermo Scientific™ Code fournisseur 4481822
  • ONLINE EXCLUSIVE PRICE
    2910.00€
    2760.00€ / Pack of 1
    Save 150.00€
    5% Off
 Article restreint
In Stock
Ajouter au panier
Ajouter au panier

missing translation for 'validMainframeMsg'

Les retours ne sont pas autorisés pour ce produit. Afficher la politique du retour.

Analytical teams that support biologic drug development require rapid, sensitive, and precise methods for protein quantitation from cell culture, fermentations broths, or purification intermediates.

Analytical teams that support biologic drug development require rapid, sensitive, and precise methods for protein quantitation from cell culture, fermentations broths, or purification intermediates. It is critical for biopharmaceutical manufacturers to be able to monitor bioreactor product titers to determine when to harvest or abort a reactor cycle. POROS CaptureSelect FSH HPLC columns incorporate the advantages of high-speed POROS chromatography resins with the unique selectivity of CaptureSelect ligands, enabling 3-minute quantitation of human follicle stimulating hormone (FSH).

Features of this class of chromotography columns:

  • Broad utility—POROS A, G, and CaptureSelect affinity ligands address most biological drug classes
  • Rapid—POROS resins offer fast quantitation or purification of immunoglobulins and fusion proteins
  • Hands-off operation—HPLC method can be automated for streamlined operation
  • Robust—delivers high-performance purification over hundreds of chromatography cycles

High Speed with High Specificity

The combination of CaptureSelect FSH affinity ligand with POROS 20 μm resin provides a high flow-rate, high performance chromatography solution for the rapid quantitation and small-scale purification of FSH.

POROS high performance chromatography allows for the quantitation of product from clarified harvest or partially purified intermediates—typically in less than 3 minutes. Moreover, only minimal sample preparation (0.2 μm filtration) is required, and the eluted product is highly purified and suitable for further analysis, including mass spectrometry.

Automation

POROS affinity chromatography columns are suitable for use with HPLC systems, allowing for the automation of chromatography, data collection, and data analysis. In addition, the immobilized affinity ligands enable one method and buffer system to be used across a class of molecules, streamlining analytical approaches.

Multiple Cycles

Proper sample preparation, adherence to column operating instructions, and the use of an optimized column cleaning regime results in strong re-use performance. POROS affinity chromatography columns can be cycled hundreds of times for cost-effective and reproducible quantitation or purification.

TRUSTED_SUSTAINABILITY

Spécification

Diamètre (métrique) 2.1 mm
Comprend Column includes EZ grip fittings and column test certificate.
Longueur (métrique) 30 mm
Pression max. 180 bar
Granulométrie 20 μm
Porosité 2000 Å
Quantité 1 colonne
Phase stationnaire Follicle Stimulating Hormone affinity ligand, humanspecific
Gamme de produits CaptureSelect, POROS
Capacité de liaison 1.5 mg/mL resin
Volume d’élution max <100 μL
Compatibilité à haut débit Automated Protocols
Type d’échantillon Biopharmaceutical Purification Sample, Bulk Drug Substance Sample, Cell Cultures
Molécule cible Follicle Stimulating Hormone
Volume (métrique) 0.1 mL
Type de colonne Affinity
Phase Affinity Separation
Matériau PEEK
Cible de purification Follicle Stimulating Hormone
Technique Antibody Affinity Chromatography
À utiliser avec (application) FPLC
Type de produit Colonne
Afficher plus Afficher moins

For Research Use Only. Not for use in diagnostic procedures.

Nom du produit
Sélectionnez un problème

En cliquant sur Soumettre, vous reconnaissez que vous pouvez être contacté par Fisher Scientific au sujet des informations que vous avez fournies dans ce formulaire. Nous ne partagerons pas vos informations à d'autres fins. Toutes les informations de contact fournies seront également conservées conformément à notre politique de confidentialité. Politique de confidentialité.