Learn More
TaqMan™ Advanced miRNA Human Serum/Plasma 96-well Plates, standard
Shop All Applied Biosystems ProductsDescription
The Applied Biosystems TaqMan Advanced Serum/Plasma 96-Well Plates, Standard, provide the convenience of pre-spotted TaqMan Advanced miRNA assays in a 96-well standard plate format. This product contains a set of 2 plates for profiling of up to 188 unique miRNAs in serum/plasma samples, and includes endogenous and exogenous miRNA controls for normalization of data results.
Features of the TaqMan Advanced Serum/Plasma 96-Well Plates include:
- Reproducibility—pre-spotted assays are designed to reduce pipetting error and minimize experimental variability
- Sample savings—requires only 2 μL of purified plasma/serum or 1–10 ng of total RNA per sample
- Updated content—assay content updated for mirBase v.21
- Easy to use—just add a mix of diluted miR-Amp and master mix and run the qPCR; no additional pipetting required
- Gold-standard TaqMan qPCR chemistry—TaqMan Advanced miRNA assays draw on Thermo Fisher Scientific's industry-leading bioinformatics assay design pipeline and verification system to help ensure high specificity and minimal cross-reactivity, even for closely-related miRNA families
Product details:
- Number of plates: 2
- Number of unique miRNAs (not including exogenous controls): 188
- Exogenous controls: cel-miR-39-3p, ath-miR159a
- Endogenous control: hsa-miR-16-5p
- Compatible with the following Applied Biosystems qPCR instruments: Viia7, 7500, QuantStudio 3, QuantStudio 5, QuantStudio 6, QuantStudio 7 Flex, and QuantStudio 12k Flex
- Recommended master mix: TaqMan Fast Advanced Master Mix
Notes
- TaqMan Advanced miRNA plates require the use of the TaqMan Advanced cDNA Synthesis Kit, which uses a universal reverse transcription (RT) chemistry to prepare the cDNA template for use with TaqMan Advanced miRNA assays for detection and quantification of mature human miRNAs in biological samples.
- These plates are not compatible with the first-generation TaqMan MicroRNA cDNA Synthesis Kit, which uses an miRNA-specific reverse transcription chemistry.
Specifications
Specifications
| Content And Storage | Store at room temperature. |
| Detection Method | Primer-probe |
| Format | 96-Well Plate |
| GC-Rich PCR Performance | High |
| PCR Method | 2-step RT-qPCR |
| Reaction Speed | Standard |
| For Use With (Equipment) | 7500 System, 7900HT System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7, ViiA™ 7 System |
| Product Line | TaqMan |
| Product Type | Advanced miRNA Human Serum/Plasma 96-Well Plate |
| Quantity | 2 Plates |
| Show More |
For Research Use Only. Not for use in diagnostic procedures.
Your input is important to us. Please complete this form to provide feedback related to the content on this product.