Miscellaneous Immobilized Affinity Ligands
- (1)
- (3)
- (1)
- (1)
- (3)
- (17)
- (5)
- (3)
- (5)
- (1)
- (2)
- (5)
- (5)
- (1)
- (1)
- (2)
- (5)
- (8)
- (10)
- (1)
- (6)
- (3)
- (1)
- (1)
Filtered Search Results
Thermo Scientific™ Pierce™ D-Galactose Agarose
Bind and affinity-purify lectins, galactosidases and other galactose-binding molecules using this beaded agarose resin with immobilized thio-alpha-D-galactose.
Thermo Scientific™ Pierce™ Iminobiotin Agarose
Agarose beads of immobilized biotin (and iminobiotin) to strongly (or reversibly) bind and remove (or purify) streptavidin or avidin proteins and conjugates from samples.
Thermo Scientific™ Detoxi-Gel™ Endotoxin Removing Gel
Bind and extract endotoxins (lipopolysaccharides or LPS) from antibody or protein samples using bulk resin or columns of immobilized Polymixin B ligand.
| Stationary Phase | Polymixin B |
|---|---|
| Type | Endotoxin Removing Gel |
| Target | Endotoxin Removal |
| Content And Storage | Store at 4°C. |
| Format | Bottle |
| Column Type | Affinity, Agarose Resin |
| Capacity (Metric) | 4000 to 6000 EU Binding per mL Gel |
| Product Line | Detoxi-Gel |
Thermo Scientific™ Pierce™ p-Aminophenyl Phosphoryl Choline Agarose
Bind and purify C-reactive protein (CRP) using these agarose beads of immobilized p-aminophenyl phosphoryl choline (APC).
Thermo Scientific™ Pierce™ Chromogenic Endotoxin Quant Kit
Chromogenic Endotoxin Quant Kits are highly sensitive endpoint assays that measure and detect endotoxin (LPS) in protein, peptide, nucleic acid, or antibody samples using the Amebocyte Lysate Assay from 0.01–1.0 EU/mL. Kits are available in reaction sizes ranging from 30 to 240.
| Shipping Condition | Wet Ice |
|---|---|
| Assay | End-point Chromogenic Assay |
| Type | Endotoxin Quantitation Kit |
| Target | Endotoxins |
| Content And Storage | • Lyophilized amebocyte lysate • E.coli endotoxin standard • Chromogenic substrate • Endotoxin-free water Store at 2–8°C upon receipt. |
| Format | Kit |
| Assay Sensitivity | 0.01 EU/mL |
| Assay Range | 0.01 to 0.1 EU/mL, 0.1 to 1.0 EU/mL |
| Product Line | Pierce |
| Detection Method | Colorimetric |
Thermo Scientific™ Pierce™ High Capacity Endotoxin Removal Spin Columns, 0.5 mL
Remove endotoxins (lipopolysaccharides or LPS) from samples before mass spectrometry using spin columns of poly(e-lysine) ligand on beaded cellulose.
| Stationary Phase | Proprietary Ligand |
|---|---|
| Type | Spin Column |
| Target | Endotoxin Removal |
| Content And Storage | Upon receipt store at 4°C. |
| Format | Spin Column |
| Form | Liquid |
| Column Type | Affinity, Cellulose Resin |
| Formulation | 8mL-capacity centrifuge columns containing 0.5mL resin |
| Capacity (Metric) | Up to 2,000,000 EU/mL |
| Product Line | Pierce |
Thermo Scientific™ Pierce™ High Capacity Endotoxin Removal Spin Columns, 0.25 mL
Remove endotoxins (lipopolysaccharides or LPS) from samples before mass spectrometry using spin columns of poly(e-lysine) ligand on beaded cellulose.
Thermo Scientific™ Pierce™ High Capacity Endotoxin Removal Spin Columns, 1 mL
Remove endotoxins (lipopolysaccharides or LPS) from samples before mass spectrometry using spin columns of poly(e-lysine) ligand on beaded cellulose.
| Stationary Phase | Proprietary Ligand |
|---|---|
| Type | Spin Column |
| Target | Endotoxin Removal |
| Content And Storage | Upon receipt store at 4°C. |
| Format | Spin Column |
| Form | Liquid |
| Column Type | Affinity, Cellulose Resin |
| Formulation | 22 mL-capacity centrifuge columns containing 1 mL resin |
| Capacity (Metric) | Up to 2,000,000 EU/mL |
| Product Line | Pierce |
Thermo Scientific™ CaptureSelect™ GoPure™ FcXP Screening Plate, 96-well, 20 μL
Thermo Scientific™ CaptureSelect™ GoPure™ FcXP 96-well screening plates contain CaptureSelect FcXP Affinity Matrix and provide a versatile platform for sample preparation, handling, and analysis.
Thermo Scientific™ POROS™ GoPure™ AAVX Screening Plate, 96-well, 20 μL
Thermo Scientific™ POROS™ GoPure™ AAVX 96-well screening plates contain POROS CaptureSelect AAVX Affinity Resin and provide a versatile platform for sample preparation, handling, and analysis.
Abcam HRV14 3C (PreScission) Protease Agarose Beads
HRV14 3C (PreScission) Protease Agarose Beads, ab286883, (previously known as #M1029) is prepared by covalent coupling active HRV14 3C Protease to activated 4% cross-linked agarose beads.
Thermo Scientific™ Pierce™ High Capacity Endotoxin Removal Resin
Remove endotoxins (lipopolysaccharides or LPS) from samples before mass spectrometry using spin columns of poly(e-lysine) ligand on beaded cellulose.
| Stationary Phase | Proprietary Ligand |
|---|---|
| Type | Resin |
| Target | Endotoxin Removal |
| Content And Storage | Upon receipt store at 4°C. |
| Format | Bottle |
| Column Type | Affinity, Proprietary Resin |
| Formulation | Proprietary ligand on beaded cellulose slurried in 20% ethanol |
| Capacity (Metric) | Up to 2,000,000 EU/mL |
| Product Line | Pierce |
Invitrogen™ EK-Away™ Resin
Specifically designed for removal of EKMaxor other enterokinase enzymes following cleavage of proteins containing the enterokinase cleavage site
| Stationary Phase | Enterokinase |
|---|---|
| Type | Resin |
| Content And Storage | EK-Away™ is provided as a 50% ethanol slurry and should be stored at +4°C. 10X binding and 10X stripping buffers are included. 7.5 ml resin will remove 250 units of enterokinase; 30 ml will remove 1000 units of EKMax™. All reagents are guaranteed stable for 6 months when stored properly. |
| Form | Liquid Suspension |
| Column Type | Affinity |
| Product Line | EK-Away |
Thermo Scientific™ GoPure™ MabCaptureC™ Screening Plate, 96-well, 20 μL
Thermo Scientific™ GoPure™ MabCaptureC™ 96-well screening plates contain MabCaptureC Affinity Matrix and provide a versatile platform for sample preparation, handling, and analysis.
Abcam Heparin Beads 6FF
Suitable for purification of heparin-dependent biomolecules e.g. antithrombin III, coagulation factors and other plasma proteins.
| Regulatory Status | RUO |
|---|