Invitrogen™ Cell Sorting Set-up Beads (for blue lasers)

Product Code. 15292018
Change view
Click to view available options
Quantity:
3 mL
Unit Size:
Pack of 2
1 product options available for selection
Product selection table with 1 available options. Use arrow keys to navigate and Enter or Space to select.
Product Code. Quantity unitSize
15292018 3 mL Pack of 2
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 1 options available.
1 options
This item is not returnable. View return policy
Product Code. 15292018 Supplier Invitrogen™ Supplier No. C16508
 Restricted Item
In Stock
Add to basket
Add to basket
This item is not returnable. View return policy

Approximate the size, emission wavelength, and intensity of many biological samples, and so can be used to calibrate a flow cytometer’s cell sorting system, including laser source, optics, and stream flow.

  • Reliable standards for flow cytometry sorter instrument setup and calibration.
  • Optimized for checking cell sorter settings such as drop delay and efficiency (cell loss during sorting).
  • Available for use with UV, blue, green/yellow, and red lasers.
  • For blue lasers
  • Fluorescent-dye infused microspheres that are excitable at 488 nm with emission in the range of 515–660 nm.
  • Consistency in production, creating ideal reference standards
  • Confidence through reliable, optimal instrument performance
  • Compatibility—use with any instrument
  • Stained internally rather than on the surface.
  • Supplied as suspensions packaged in dropper vials for convenient dispensation and are available in a choice of four colors (UV, blue, green/yellow, red) to match your laser.
  • Selected to provide emission peaks coincident with cells labeled with commonly used fluorescent dyes.
TRUSTED_SUSTAINABILITY

Specifikationer

Diameter (Metric) 6 μm
Content And Storage Contains 2 vials Cell Sorting Set-up Beads (1.5 mL per vial). Store in refrigerator (2–8°C) and protect from light.
Format Suspension
For Use With (Equipment) Flow Cytometer
Quantity 3 mL
Detection Method Fluorescence
Excitation Wavelength Range 488⁄515
Stain Configuration Core
Shipping Condition Room Temperature
Product Type Cell Sorting Set-up Beads
What are Cell Sorting Set-up Beads used for?

Cell Sorting Set-up Beads (Cat. Nos. C16506, C16507, C16508, and C16509) are reliable standards for flow cytometry cell sorter instrument setup and calibration. The Cell Sorting Set-up Beads approximate the size, emission wavelength, and intensity of many biological samples, and so can be used to calibrate a flow cytometer's cell sorting system, including laser source, optics, and stream flow. The beads are optimized for checking cell sorter settings such as drop delay and efficiency (cell loss during sorting). Cell Sorting Set-up Beads are available for use with UV, blue, green/yellow, and red lasers.

For Research Use Only. Not for use in diagnostic procedures.