missing translation for 'onlineSavingsMsg'
Learn More

Thermo Scientific™ GeneJET Plasmid Miniprep Kit

Produktkod. 10319699 Handla allt< titel> Produkter
missing translation for 'orderingAttributeHoverText'
Quantity:
250 Preps
50 Preps
Förpackningsstorlek
250 reactions
75mL
Each
Denna artikel kan inte returneras. Se returpolicy

Produktkod. 10319699

missing translation for 'mfr': Thermo Scientific™ K0502

Please to purchase this item. Need a web account? Register with us today!

Denna artikel kan inte returneras. Se returpolicy

Thermo Scientific GeneJET Plasmid Miniprep Kit utilizes an exclusive silica-based membrane technology in the form of a convenient spin column.

Thermo Scientific GeneJET Plasmid Miniprep Kit utilizes an exclusive silica-based membrane technology in the form of a convenient spin column. The kit recovers up to 20 μg of high copy plasmid DNA per isolation procedure.

Highlights

  • Efficient—high yields of up to 20 μg of high quality plasmid DNA
  • Fast—procedure takes less than 14 minutes
  • Convenient—no phenol/chloroform extraction or alcohol precipitation required
  • Pure—purified DNA is immediately ready to use

Applications

Fast isolation of high purity plasmid DNA suitable for all conventional molecular biology procedures, including:

  • FastDigest or conventional restriction digestion
  • Automated fluorescent and radioactive sequencing
  • PCR
  • In vitro transcription
  • Transformation

Principle

A bacterial culture is harvested and lysed. The lysate is then cleared by centrifugation and applied on the silica column to selectively bind DNA molecules at a high salt concentration. The adsorbed DNA is washed to remove contaminants, and the pure plasmid DNA is eluted in a small volume of elution buffer or water. The purified DNA is ready for immediate use in all molecular biology procedures, such as fast and conventional digestion with restriction enzymes, PCR, in vitro transcription, transformation, and automated sequencing.

Components

  • Resuspension Solution
  • Lysis Solution
  • Neutralization Solution Wash Solution (concentrated)
  • RNase A Solution
  • Elution Buffer
  • Spin Columns
  • Collection Tubes
  • Detailed Protocol

Related Products

  • RNase A (Part No.: R1253)
  • Elution Buffer for GeneJET Plasmid Miniprep Kit (Part No.: R1263)
  • Lysis Solution for GeneJET Plasmid Miniprep Kit (Part No.: R1223)
  • Resuspension Solution for GeneJET Plasmid Miniprep Kit (Part No.: R1213)
  • Neutralization Solution for GeneJET Plasmid Miniprep Kit (Part No.: R1233)
  • Wash Solution for GeneJET Plasmid Miniprep Kit (Part No.: R1243)
  • Binding Buffer for GeneJET Plasmid Miniprep Kit(Part No.: R1331)
TRUSTED_SUSTAINABILITY

Specifikationer

Column Type Spin Column
Format Spin Column
Isolation Technology Silica Column
Scale Mini
Sample Type Bacteria
For Use With (Application) PCR, Cloning, Sequencing, Transformation, Nucleic Acid Labeling, In Vitro Transcription
High-throughput Compatibility Compatible (Vacuum manifold)
Prep Scale < 100 μg (Small-Scale) Plasmid DNA
Product Line GeneJET
Product Type Plasmid MiniPrep Kit
Quantity 50 Preps
Target Plasmid DNA
Test Time <14 min
Visa mer Visa mindre
compliance-icons
Produktbeteckning
  • GeneJET Plasmid Miniprep Kit
Signalord
  • Warning
Riskkategorier
  • Acute toxicity Category 4
  • Serious eye damage/eye irritation Category 2
  • Skin corrosion/irritation Category 2
Faroangivelser
  • H302-Harmful if swallowed.
  • H315-Causes skin irritation.
  • H319-Causes serious eye irritation.
Skyddsangivelse
  • P264-Wash hands thoroughly after handling.
  • P270-Do not eat, drink or smoke when using this product.
  • P280-Wear protective gloves/protective clothing/eye protection/face protection.
  • P301+P310-IF SWALLOWED: Immediately call a POISON CENTER/doctor /
  • P302+P352-IF ON SKIN: Wash with plenty of water/soap.
  • P305+P351+P338-IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P330-Rinse mouth.
  • P332+P313-If skin irritation occurs: Get medical advice/attention.
  • P337+P313-If eye irritation persists: Get medical advice/attention.
  • P362+P364-Take off contaminated clothing and wash it before reuse.
  • P501b-Dispose of contents/container in accordance with local/regional/national/international regulations.
Kompletterande information
  • MIXTURE LIST-Contains : guanidine hydrochloride

For Research Use Only. Not for use in diagnostic procedures.

Korrigering av produktinnehåll

Din input är viktig för oss. Fyll i det här formuläret för att ge feedback relaterad till innehållet på denna produkt.

Produkttitel

Genom att klicka på Skicka bekräftar du att du kan bli kontaktad av Fisher Scientific angående feedbacken du har lämnat i detta formulär. Vi kommer inte att dela din information för andra ändamål. All kontaktinformation som tillhandahålls ska också underhållas i enlighet med vår Sekretesspolicy.

Tack! Din feedback har skickats. Fisher Scientific arbetar alltid för att förbättra vårt innehåll åt dig. Vi uppskattar din feedback.