ICP, ICP-MS Multi Element Standard in 2 to 5% Nitric Acid (15 Elements), Reagecon
Shop All Reagecon Products

Description
- Raw materials used are assayed by titration and ICP-MS
- Separate standards used to control or calibrate titration/ICP-MS
- Manufactured gravimetrically using mass balance
- 100% less sum of all impurities
- ISO/IEC 17025
- For testing of ICP/ICP-MS standards using ICP-MS
- For calibration of laboratory balances
- For temperature calibration -90 to 650 °C
- For density measurement using Oscillating U-tube and Bingham pycnometry
- For certain complexometric titrations
- GHS/OSHA compliant, REACH
- Produced in highly controlled cleanroom environment using ultra-pure water, triple distilled acids and triple leached pre-cleaned bottles
- All uncertainties of measurement calculated according to Eurachem/CITAC guidelines and reported at 95% confidence level
Specifications
Specifications
| Packaging | HDPE triple-leached |
| Analyte or Component Names | 100 μg/mL each of aluminum, barium, calcium cadmium, cobalt, chromium, copper, iron, magnesium, manganese, sodium, nickel, lead, titanium, zinc |
| Physical Form | Liquid |
| Technique | ICP, ICP-MS, AA, Ion Chromatography, XRF, Cation Measurement |
| UN Number | 1760 |
| Type | ICP/ICP-MS Standard |
| Element | Al, Ba, Ca, Cd, Co, Cr, Cu, Fe, Mg, Mn, Na, Ni, Pb, Ti, Zn |
| Solvent or Matrix | 2 to 5% HNO3 |
| Quantity | 100 mL |
Safety and Handling
Product Identifier
- MULTIELEMENT ICP STANDARD
- Danger
- Carcinogenicity Category 1A
- Serious eye damage/eye irritation Category 2
- Skin corrosion/irritation Category 2
- H315-Causes skin irritation.
- H319-Causes serious eye irritation.
- H350-May cause cancer.
- P280-Wear protective gloves/protective clothing/eye protection/face protection.
- P305+P351+P338-IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P308+P313-IF exposed or concerned: Get medical advice/attention.
- P332+P313-If skin irritation occurs: Get medical advice/attention.
- P405-Store locked up.
- P501b-Dispose of contents/container in accordance with local/regional/national/international regulations.
- MIXTURE LIST-Contains : cobalt carbonate, nitric acid