Thermo Scientific™ Polyacrylamide Desalting Columns, 6K MWCO, 10 mL
Shop All Thermo Scientific ProductsDescription
Thermo Scientific™ Pierce Polyacrylamide Desalting Columns are ready-to-use, disposable, gel-filtration columns for separating proteins and other macromolecules from low molecular-weight buffer salts and reagents.
Highlights:
Formats: pre-packed 5mL and 10mL gravity-flow columns (1.8K and 6K MWCO only) and 0.7mL microcentrifuge columns (7K MWCO only)
Resin type: porous, beaded polyacrylamide
Bead size: 90 to 180μm dia. (6K and 7K resins); 45 to 90μm dia. (1.8K resin)
Flow rate: up to 2.5mL/min (fast compared to other desalting resins)
Chemical stability: compatible with water, salt solutions, many organic solvents and alkaline or acidic conditions
Mechanical stability: medium rigidity compared to other gel-filtration resins
Heat stability: resin is autoclavable dry or in solution at a neutral pH for 30 minutes at 120°C without affecting its chromatographic properties
Item-Specific Features:
- 1.8K MWCO resin (5mL column only) recovers all peptides and proteins larger than 1800 daltons with high efficiency; only salts and very small compounds (less than 100 MW) are removed fully
- 6K MWCO resin (5mL and 10mL columns only) recovers proteins larger than 6000 daltons with high efficiency; salts and small compounds (less than 1000 MW) are removed fully
- 7K MWCO resin (0.7mL spin column only) recovers proteins larger than 7000 daltons with high efficiency; salts and small compounds (less than 1000 MW) are removed fully
Includes:
Pre-packed columns with top and bottom caps
Recommended for:
Removing salts from protein solutions; Removing phenol from nucleic acid preparations; Separating excess crosslinker from conjugate preparations; Removing excess derivatizing agents from modified proteins; Removing unreacted dye from fluorescent antibodies; Removing free radiolabel from labeled proteins; Exchanging one buffer for another
Specifications
Specifications
| Product Type | Desalting Column |
| Content And Storage | Upon receipt store at room temperature or 4°C. Product shipped at ambient temperature. |
| Format | Gravity Flow Column |
| Purification Target | Buffer Exchange, Protein |
| Column Type | Size-exclusion, Polyacrylamide Resin |
| MWCO | 6.0 kDa |
| Disposable | Single-use |
| Quantity | 5 Columns |
| Volume (Metric) | 2.5 mL |