missing translation for 'onlineSavingsMsg'
Learn More

Thermo Scientific™ TraceGOLD TG-1MT Metal GC Columns

Product Code. 15820920 Shop All Thermo Scientific Products
Change view
Click to view available options
Length (Metric):
10 m
12 m
15 m
30 m
5 m
6 m
Diameter (Metric) Inner:
0.25 mm
0.53 mm
Film Thickness:
0.1 μm
0.15 μm
0.25 μm
0.5 μm
0.88 μm
1 μm
2.65 μm
Unit Size:
Each
Product Code. Length (Metric) Diameter (Metric) Inner Film Thickness unitSize
15820920 10 m 0.53 mm 2.65 μm Each
12602745 5 m 0.53 mm 0.88 μm Each
15257488 12 m 0.53 mm 1 μm Each
12612745 5 m 0.53 mm 0.1 μm Each
11805712 30 m 0.25 mm 1 μm Each
11835712 6 m 0.53 mm 0.15 μm Each
11895702 30 m 0.25 mm 0.5 μm Each
11885702 30 m 0.25 mm 0.25 μm Each
11875702 15 m 0.25 mm 0.25 μm Each
9 options
This item is not returnable. View return policy

Product Code. 15820920

Brand: Thermo Scientific™ 26M993480

Only null left
Add to basket
Add to basket
This item is not returnable. View return policy

Push the limits of your analyses with these nonpolar, metal columns designed for elevated temperature use.

Push the limits of your analyses with Thermo Scientific™ TraceGOLD™ TG-1MT GC Columns. These nonpolar, metal columns allow you to work a temperatures up to 430°C with no compromise in performance when analyzing highly active and aggressive compounds.

Engineered for Superior Performance:
  • Nonpolar, 100% dimethyl polysiloxane
  • Low bleed for excellent signal-to-noise ratio, sensitivity and mass spectral integrity
  • Stable to 430°C
  • Applications:
  • Hydrocarbons
  • Solvent impurities
  • Polychlorinated biphenyl (PCB) congeners
  • Aroclor mixes
  • Simulated distillation
  • Drugs of abuse
  • Natural gas odorants
  • Essential oils
  • Pesticides
  • A Leap Forward in Performance with Low Bleed and Superior Inertness:
  • A low bleed, stable column produces consistent results.
  • Low baseline noise enables improved limits of detection with enhanced resolution of low level analytes. Minimizing column bleed extends the column lifetime, leading to higher productivity.
  • Reducing column bleed increases reproducibility of the stationary phase over time, resulting in greater run-to-run and batch-to-batch reproducibility.
  • Superior inertness ensures excellent peak shape and sensitivity, especially for highly active or difficult compounds.
  • Recommended For:
  • Hydrocarbons
  • Gasoline range
  • Chlorinated aromatics
  • Organochlorine pesticides
  • Organophosphorous pesticides
  • Polycyclic aromatic hydrocarbons (PAHs)
  • Paraffins
  • Polywax
  • Pyrethroids
  • Semivolatiles
  • Xylenes
  • Similar To:
  • MXT™-1
  • DB-1
  • DB-1MS
  • HP-1
  • HP-1MS
  • Ultra-1
  • SPB™-1
  • Equity™-1
  • MDN-1
  • CP-Sil 5 CB
  • VF-1ms
  • ZB-1HT
  • TRUSTED_SUSTAINABILITY

    Specifications

    Max. Temperature Up to 430°C
    Diameter (Metric) 0.53 mm
    Diameter (Metric) Inner 0.53 mm
    Product Line TraceGOLD
    Stationary Phase TraceGOLD™ TG-1MT
    USP Type G2
    For Use With (Application) Hydrocarbons Anaylsis, GC/MS for Hydrocarbons, GC/MS for Gasoline Range Organics (GROs), GC/MS for Drugs of Abuse, GC/MS for PCBs
    Film Thickness 2.65 μm
    Length (Metric) 10 m
    Polarity Non-Polar

    Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

    Product Title
    Select an issue

    By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.