Combination Ion Selective Electrodes
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (3)
- (38)
- (1)
- (2)
- (1)
- (1)
- (1)
- (2)
- (5)
- (4)
- (2)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (22)
- (1)
- (1)
- (1)
- (1)
- (1)
- (4)
- (1)
- (1)
- (1)
- (4)
- (2)
- (1)
- (2)
- (39)
- (18)
- (6)
- (1)
- (11)
- (7)
- (1)
- (1)
- (3)
- (5)
- (1)
- (2)
- (8)
- (1)
- (3)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (29)
- (1)
- (2)
- (1)
- (1)
- (2)
- (2)
- (1)
- (1)
- (3)
- (1)
- (1)
- (5)
- (1)
- (1)
- (1)
- (42)
- (7)
- (1)
- (4)
- (2)
- (1)
- (2)
- (12)
- (6)
- (1)
- (6)
- (25)
- (3)
- (2)
Filtered Search Results
Fisherbrand™ Combined Ion-Selective Electrode
Converts activity of a specific ion dissolved in a solution into an electrical potential. Fisherbrand™ Combined Ion-Selective Electrode is compatible with all pH/mV meters or ionometers.
| Filling Solution Type | ISAB/ISE |
|---|
METTLER TOLEDO™ Ion Selective Electrodes (ISE)
A selection of ISE probes for detecting concentration of various free ions.
| Type | Ion Selective Electrode |
|---|---|
| Length (Metric) | 120 mm |
| Length (English) | 4.75 in. |
| Material | Epoxy |
Thermo Scientific™ Orion™ Fluoride Ion Selective Electrodes
Quickly, simply, accurately and economically measure free fluoride ions in aqueous solutions.
| Diameter (English) Body | 0.51 in. |
|---|---|
| Length (Metric) Cable | 1m |
| Length (Metric) | 110mm |
| For Use With (Equipment) | ISE Meter |
| Temperature (English) Operating | Continuous: 32 to 176 °F; Intermittent: 176°F to 212°F |
| Refillable | Yes |
| Length (English) | 4.33 in. |
| Length (English) Cable | 39 in. |
| Material | Epoxy |
| Filling Solution Type | 900061 (9609BNWP and 960900); 900001 with 900100 single junction reference electrode (9409BN, 9409SC, and 940900) |
| Temperature (Metric) Operating | 0°C to 80°C (Continuous), 80°C to 100°C (Intermittent) |
| Diameter (Metric) Body | 13mm |
Cole-Parmer™ Combination Ion-Selective Electrode (ISE)
Fast and accurate Ion-selection electrodes do not require an external reference—they're easier to use than separate sensing and reference half-cell electrodes.
Thermo Scientific™ Orion™ Chloride Ion Selective Electrodes
Easily and reliably analyze free chloride ions in aqueous solutions. Provides quick, accurate and economical measurements.
| Type | Combination ISE |
|---|---|
| For Use With (Equipment) | Chloride electrodes can be used on any ISE meter with a BNC connection The electrodes can also be used on meters with a variety of inputs when an adapter cable is used. |
Thermo Scientific™ Orion™ Calcium Ion Selective Electrodes
Measure calcium ions in aqueous solutions simply, accurately and economically.
Fisherbrand™ accumet™ Chloride Combination Electrode - Mercury-Free
Typical applications include water/wastewater, soil, dairy, meats, tomato/vegetable products.
Thermo Scientific™ Orion™ ROSS™ Sodium Ion Selective Electrodes
Measure sodium ions in aqueous solution quickly, accurately and economically.
| Diameter (English) Body | 0.47 in |
|---|---|
| Length (Metric) Cable | 1 M |
| Length (Metric) | 120 mm |
| For Use With (Equipment) | ISE Meter |
| Temperature (English) Operating | 32 to 176°F |
| Operating Range (Metric) | Saturated to 10-6 M, saturated to 0.02ppm |
| Length (English) | 4.72 in |
| Length (English) Cable | 39.3 in. |
| Material | Glass |
| Filling Solution Type | 900010 for regular Na+ (> 10-5 M or 0.2 ppm), 900012 for low level Na+ (< 10-5 M or 0.2 ppm) |
| Temperature (Metric) Operating | 0°C to 100°C |
| Measurement Range |
|
Thermo Scientific™ Orion™ Iodide Ion Selective Electrodes
Get fast, stable and reliable iodide ions readings in aqueous solutions.
| For Use With (Equipment) | ISE Meter |
|---|
Thermo Scientific™ Orion™ Nitrate Ion Selective Electrodes
Measurements are quick, simple, accurate and economical. Analyze free nitrate ions in aqueous solutions reliably at low limits of detection.
| Junction | Sure-Flow Junction |
|---|---|
| Drift | drift-free potentials |
Thermo Scientific™ Orion™ Ionplus™ Sure-Flow™ Cyanide Combination Ion Selective Electrode
Measure cyanide ions in aqueous solutions quickly, simply, accurately and economically.
| For Use With (Equipment) | ISE Meter |
|---|---|
| Junction | Sure-Flow Junction |
Oakton Combination Ion-Selective Electrode (ISE), Fluoride (F)
Save money and frustration with the Combination Ion-Selective Electrode (ISE), Fluoride (F) - cost effective and easy to use.
Mettler Toledo™ perfectION™ Ion-Selective Epoxy Combination Electrodes
Allows quick and easy determination of concentration and activity of a variety of dissolved ions.
Mettler Toledo™ perfectION™ Combination Electrodes
Enables optimum contact between the electrolyte and measurement solution
| Applications | Can flow easily through the junction and junction is optimally cleaned between the measurements and the electrolyte can be simply emptied and refilled |
|---|---|
| For Use With (Equipment) | All pH, mV Meters or Ionometers |
| Filling Solution Type | ISA |
Thermo Scientific™ Orion™ Carbon Dioxide Combination Ion Selective Electrode
Measure carbon dioxide, carbonate and bicarbonate in aqueous solutions quickly, accurately and economically.